Start where the person approaches
Stand on the face being checked. Establish whether the door opens towards or away from you, then identify the direction from which someone reaches it. Check the other usable direction separately.
REACH THE HANDLE · OPEN THE DOOR · MOVE THROUGH
A wide opening is only part of an accessible doorway. Explore the clear floor space needed to approach a manual hinged door, reach its handle and move through it.
Your selected dimensions will appear here.
These results compare selected dimensions with a named US reference. They do not establish whole-door compliance or determine which rules apply to your project.
Stand on the face being checked. Establish whether the door opens towards or away from you, then identify the direction from which someone reaches it. Check the other usable direction separately.
Measure depth perpendicular to the closed door. Measure the extra width beyond the indicated jamb. Most choices need latch-side space; a hinge-side push approach needs its extension beyond the hinge.
Open the door to 90° and measure from the face of the leaf to the opposing stop. A 32 in (812.8 mm) clear opening is the usual minimum; an opening deeper than 24 in requires 36 in (914.4 mm).
The planner follows ADA 2010 Table 404.2.4.1 for manual swinging doors, including its four footnotes and both hinge-side pull alternatives. Clear opening is a separate §404.2.3 check.
US customary values are converted exactly here. The standard also prints rounded metric equivalents; those are not substituted into this calculation.
Read the official door requirements ↗Furniture, a thick wall or a column can change the available approach. If an obstruction projects more than 8 in within 18 in of the latch, review the front-approach requirement in §404.2.4.3. Door pairs in series need their own assessment.
The drawing is an original schematic. It does not resolve a building footprint or a recessed doorway.
Explore the Access Board door guide ↗Room to open a door belongs to a continuous accessible journey. Check the arrival route, ramps, landings, information and destination with the people who use them.
Special exceptions, hospital patient-room doors and automatic, sliding, folding or revolving doors are outside this planner.
Physical accessibility guide