REACH THE HANDLE · OPEN THE DOOR · MOVE THROUGH

Leave room for
the whole movement.

A wide opening is only part of an accessible doorway. Explore the clear floor space needed to approach a manual hinged door, reach its handle and move through it.

01

Choose your approach

ADA 2010 · manual hinged doors · one face of the door at a time.

Your measurements stay in this tab. Use copy, download or print to keep a summary.

Door hardware

For this table, spring hinges and gravity hinges do not count as closers. Select the hardware actually present.

Checks use exact inch dimensions: 1 in = 25.4 mm. Switching units preserves the entered measurement.

Compare your measured space

Optional. Leave an unknown dimension blank; it stays unverified.

From the closed door face into the approach space, at right angles to the doorway.

Extra clear floor width beside the doorway. Do not include the doorway width.

With the door open 90°, measure between its face and the opposite stop. This is not the nominal door leaf width.

This changes the separate clear-opening minimum from 32 in to 36 in. Leaving it unchecked assumes an opening no more than 24 in deep.

02

Make space to manoeuvre

Your selected dimensions will appear here.

Three measurements, different purposes.

Start where the person approaches

Stand on the face being checked. Establish whether the door opens towards or away from you, then identify the direction from which someone reaches it. Check the other usable direction separately.

Mark a clear floor rectangle

Measure depth perpendicular to the closed door. Measure the extra width beyond the indicated jamb. Most choices need latch-side space; a hinge-side push approach needs its extension beyond the hinge.

Measure the usable opening

Open the door to 90° and measure from the face of the leaf to the opposing stop. A 32 in (812.8 mm) clear opening is the usual minimum; an opening deeper than 24 in requires 36 in (914.4 mm).

Know what this plan covers.

One table, clearly named

The planner follows ADA 2010 Table 404.2.4.1 for manual swinging doors, including its four footnotes and both hinge-side pull alternatives. Clear opening is a separate §404.2.3 check.

US customary values are converted exactly here. The standard also prints rounded metric equivalents; those are not substituted into this calculation.

Read the official door requirements ↗

Watch for recesses and obstacles

Furniture, a thick wall or a column can change the available approach. If an obstruction projects more than 8 in within 18 in of the latch, review the front-approach requirement in §404.2.4.3. Door pairs in series need their own assessment.

The drawing is an original schematic. It does not resolve a building footprint or a recessed doorway.

Explore the Access Board door guide ↗

Continue along the route

Room to open a door belongs to a continuous accessible journey. Check the arrival route, ramps, landings, information and destination with the people who use them.

Special exceptions, hospital patient-room doors and automatic, sliding, folding or revolving doors are outside this planner.

Physical accessibility guide
Explore all physical tools